Каталог
The TRCP Series Rogowski current probes are equipped with a BNC connector and work with any instrument supporting the BNC interface. Rogowski probes allow you to easily connect to large connection points such as bus bars or connect to small IC legs on a MOSFET or IGBT.
Key features
- TRCP0300
- AC only
- 9 Hz to 30 MHz
- 250 mA to 300 A peak
- TRCP0600
- AC only
- 12 Hz to 30 MHz
- 500 mA to 600 A peak
- TRCP3000
- AC only
- 1 Hz to 16 MHz
- 500 mA to 3,000 A peak
Applications
- Motor drives
- Inverters
- Power supplies
- Industrial
TRCP0300-TRCP0600 Current Probes
The TRCP0300 and TRCP0600 are designed for use on small form factor components. These AC-only Rogowski probes have a thin, flexible coil that can easily be wrapped around test points such as the leg of a transistor.
TRCP3000 Current Probe
The TRCP3000 has a larger coil that is capable of handling large overload currents without damage. This probe is easy to use and can be inserted into places that are hard to reach and can be wrapped around larger test points such as bus bars.
Ordering information
TRCP Series Rogowski Current Probes
- TRCP0300
-
300 A, AC-Only Rogowski Current Probe
- TRCP0600
- 600 A, AC-Only Rogowski Current Probe
- TRCP3000
- 3,000 A, AC-Only Rogowski Current Probe
Standard accessories
- AC power adapter
- 50 Ω BNC cable
Options
Service options
- Opt. C3
- Calibration Service 3 Years
- Opt. C5
- Calibration Service 5 Years
- Opt. D1
- Calibration Data Report
- Opt. D3
- Calibration Data Report 3 Years (with Opt. C3)
- Opt. D5
- Calibration Data Report 5 Years (with Opt. C5)
- Opt. R3
- Repair Service 3 Years (including warranty)
- Opt. R3DW
-
Repair Service Coverage 3 Years (includes product warranty period). 3-year period starts at time of instrument purchase
- Opt. R5
- Repair Service 5 Years (including warranty)
- Opt. R5DW
-
Repair Service Coverage 5 Years (includes product warranty period). 5-year period starts at time of instrument purchase
| Модель | Максимальный ток | Минимальный ток | Полоса частот | Время нарастания сигнала |
| TRCP3000 |
3000 А |
500 мА |
16 МГц |
— |
Specifications
| TRCP0300 | TRCP0600 | TRCP3000 | |
| Frequency range | 9 Hz to 30 MHz | 12 Hz to 30 MHz | 1 Hz to 16 MHz |
| Peak current | 300 A | 600 A | 3000 A |
| Minimum current | 250 mA | 500 mA | 500 mA |
| Sensitivity | 20 mV/A | 10 mV/A | 2 mV/A |
| External probe attenuation setting on scope | 50X | 100X | 500X |
| Accuracy (typical) | +/- 2% of reading | +/- 2% of reading | +/- 2% of reading |
| Coil diameter | 1.7 mm | 4.5 mm | 8.5 mm |
| Termination | 1 MΩ BNC | 1 MΩ BNC | 1 MΩ BNC |