Каталог
Модель Название | Описание | |
Fluke 772 | Калибратор-мультиметр с клещами для измерения слабых токов
Принадлежности, входящие в комплект поставки:
|
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 772 mA Clamp Meters. It’s designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Here are some specific ways the Fluke 772 Clamp Meters will help you:
Milliamp Clamp Features |
Application |
How it saves time and money |
Measure mA signals for PLC and control system analog I/O without breaking the loop. |
Measures low level dc current |
Correlate process indication with real physical value |
Measure output signals from transmitters without breaking the loop |
Maintain and troubleshoot process and automation equipment without breaking the loop |
No disruption to the process |
Detachable clamp with extension cable |
Measurements in tight locations |
Enables measurements in difficult situations |
Measurement Spotlight |
Illuminates hard to see wires in dark enclosures |
Measurement process is easier and quicker |
Measure up to 99.9 mA range non-contact |
Wide range of measurements |
Measures 10 to 50 mA signals in older control systems |
Automatic power off |
After 15 minutes and 2 minute automatic off for backlight and spotlight |
Saves battery life |
The 772 mA Clamp Meter features:
- Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without ”breaking the loop”
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- Automatically change the 4 to 20 mA output for remote testing
What’s the difference between the 77X models?
Fluke-771 |
Fluke-772 |
Fluke-773 |
|
|
Non-contact mA loop measurement |
Integrated mA loop troubleshooting |
Advanced process troubleshooting |
mA measure, jaw |
|||
mA measure, in circuit |
|
||
Loop power |
|
||
mA source |
|
||
DCV measure |
|
|
|
DCV source |
|
|
|
mA scaled output |
|
|
|
mA in / out |
|
|
Specifications |
|
Diameter of measurable conductor |
0.177 or 4.5 mm max |
Operating temperature |
-10 to 50 ºC |
Storage Temperature |
-25 to 60ºC |
Operating Humidity |
< 90% @ <30 ºC, < 75% @ 30 to 55ºC |
Operating Altitude |
0 to 2000 m |
IP Rating |
IP 40 |
Size |
59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.) |
Weight |
260G, (9.1 oz.) |
Vibration |
Random 2 g, 5 to 500 Hz |
Shock |
1 meter drop test (except the jaw) |
EMI/RFI |
Meets EN61326-1 |
Temperature Coefficient |
0.01% ºC |
Power, battery life |
(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical |
Warranty |
Three years for electronics one year for cable and clamp assembly |
Functional Specifications |
|
mA measurement |
Resolution and Range: 0 to 20.99 mA |
mA measurement |
Resolution and Range: 0 to 24.00 mA |
mA source (Maximum mA Drive: |
Resolution and Range: 0 to 24.00 mA |
mA simulate |