Каталог

Fluke 116/323 Kit

цена по запросу
шт.

Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Описание Характеристики Файлы

Модель Название

Описание

Fluke 116/323 Kit

Includes:
  • Fluke 116 HVAC Multimeter with Temperature and Microamps
  • Fluke 323 True-rms Clamp Meter

 

Test Leads
TL225 Комплект тестовых проводов адаптера напряжения помех TL225 SureGrip™
 
This kit is a direct replacement for the obsolete 116/322 HVAC combo kit.

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Multimeter and Clamp Meter Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL175 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.

  • 400 A ac current measurement.
  • 600 V ac and dc voltage measurement.
  • True-rms ac voltage and current for accurate measurements on non-linear signals.
  • Resistance measurement up to 40 kΩ with continuity detection.
  • Slim, ergonomic design.
  • CAT IV 300V/CAT III 600 V safety rating.

 

Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications

Maximum voltage between any terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

Display

6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating Temperature

-10 °C to + 50 °C

Storage Temperature

-40 °C to + 60 °C

Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery Life

400 hours typical, without backlight

 

Accuracy Specifications

DC millivolts

Range

600.0 mV

Resolution

0.1 mV

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range/Resolution

6.000 V / 0.001 V

Range/Resolution

60.00 V / 0.01 V

Range/Resolution

600.00 V / 0.1 V

Accuracy

± ([% of reading] + [counts]): 0.5% + 2

Auto volts

Range

600.0 V

Resolution

0.1 V

Accuracy

2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts1 true-rms

Range

600.0 mV

Resolution

0.1 mV

Accuracy

1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

AC volts1 true-rms

Range/Resolution

6.000 V / 0.001 V

Range/Resolution

60.00 V / 0.01 V

Range/Resolution

600.0 V / 0.1 V

Accuracy

1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

Continuity

Range

600 Ω

Resolution

1 Ω

Accuracy

Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.

Ohms

Range/Resolution

600.0 Ω / 0.1 Ω

Range/Resolution

6.000 kΩ / 0.001 kΩ

Range/Resolution

60.00 kΩ / 0.01 kΩ

Range/Resolution

600.0 kΩ / 0.1 kΩ

Range/Resolution

6.000 MΩ / 0.001 MΩ

Accuracy

0.9 % + 1

Range/Resolution

40.00 MΩ / 0.01 MΩ

Accuracy

1.5 % + 2

Diode Test

Range/Resolution

 2.000 V / 0.001 V

Accuracy

 0.9% + 2

Capacitance

Range/Resolution

1000 nF / 1 nF

Range/Resolution

10.00 μF / 0.01 μF

Range/Resolution

100.0 μF / 0.1 μF

Range/Resolution

9999 μF / 1 μF

Range/Resolution

100 μF to 1000 μF

Accuracy

1.9% + 2

Range/Resolution

> 1000 μF

Accuracy

5% + 20%

LoZ capacitance

Range

1 nF to 500 μF

Accuracy

10% + 2 typical

Temperature2 (Type-K thermocouple)

Range/Resolution

-40 °C to 400 °C / 0.1 °C

Accuracy

1% + 102

Range/Resolution

-40 °F to 752 °F / 0.2 °F

Accuracy

1% + 182

AC μamps true-rms (45 Hz to 500 Hz)

Range/Resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

DC μamps

Range/Resolution

600.0 μA / 0.1 μA

Accuracy

1.0% + 2

Hz (V or A input)2

Range/Resolution

99.99 Hz / 0.01 Hz

Range/Resolution

999.99 Hz / 0.1 Hz

Range/Resolution

9.999 Hz / 0.001 Hz

Range/Resolution

50.00 Hz / 0.01 Hz

Accuracy

0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Mechanical & General Specifications

Size

167 x 84 x 46 mm (6.57" x 3.31" x 1.82")

Weight

550 g

Warranty

3 years

Fluke 323 True-rms Clamp Meter

Specifications

AC current

Range 400.0 A

 

Accuracy

2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)

AC voltage

Range

600.0 V

Accuracy

1.5 % ± 5 digits

DC voltage

Range

600.0 V

Accuracy

1.0 % ± 5 digits

Resistance

Range

400.0 Ω/ 4000 Ω

Accuracy

1.0 % ± 5 digits

Continuity

≤ 70 Ω

AC response

True-rms

Data hold

Yes

Size

H x W x D (mm)

207 x 75 x 34

Max wire diameter

30 mm (600 MCM)

Weight

265 g

Category rating

CAT III 600 V
CAT IV 300 V

Warranty

Two-year

Связанные приборы