Fluke 51 II

Single Input Digital Thermometer including:

  • Impact absorbing holster
  • One 80PK-1 bead probe thermocouple

Fluke 52 II

Dual Input Digital Thermometer including:

  • Impact absorbing holster
  • Two 80PK-1 beaded probe thermocouples

Fluke 53 II

Single Input Digital Thermometer with data logging including:

  • Impact absorbing holster
  • One 80-PK-1 bead probe thermocouple

Fluke 54 II

Dual Input Digital Thermometer including:

  • Impact absorbing holster
  • Two 80PK-1 bead probe thermocouples

 

Программное обеспечение

FlukeView Forms

Программа FlukeView Forms и кабель для подключения к компьютеру

 

Сумки и Чехлы

C101

C101 Твердый футляр

C50

C50 Сумка для измери-тельного прибора

C510

C510 Кожаный чехол для измерительного прибора

C550

C550 Сумка для инструмента

TPAK

TPAK Комплект ToolPak

CXT170

Футляр повышенной прочности CXT170

 

Температура

700TC2

700TC2 Thermocouple Plug Kits (5 types)

80CJ-M

80CJ-M Мини-переходник с наружной резьбой

80CK-M

80CK-M Мини-переходник с наружной резьбой

80PJ-1

80PJ-1 Точечные щупы (типа К)

80PJ-EXT

80PJ-EXT Наборы проводов-удлинителей (типа J)

80PK-1

80PK-1 Точечные щупы (типа К)

80PK-22

80PK-22 Immersion Probe

80PK-24

80PK-24 Воздушный зонд (типа К)

80PK-25

80PK-25

80PK-26

80PK-26 Универсальный датчик (типа К)

80PK-27

80PK-27 Промышленный плоский зонд (типа К)

80PK-3A

80PK-3A Плоский зонд (типа К)

80PK-8

80PK-8 Датчик температуры схомутом для труб (типа К)

80PK-EXT

80PK-EXT Наборы проводов-удлинителей (типа К)

80PT-EXT

80PT-EXT Наборы проводов-удлинителей (типа Т)

Laboratory accuracy. Wherever you go.

The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool.

Fluke 50 Series II products features:

  • Relative time clock on MIN, MAX, and AVG provides a time reference for major events
  • Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
  • Measures J, K, T, and E-types of thermocouples
  • Readout in ºC, ºF, or Kelvin (K)
  • Splash and dust resistant case protected by impact absorbing holster
  • User-friendly front panel is easy to set up and operate
  • Sleep mode increases battery life; typical 1000-hour battery life
  • Battery door allows easy battery replacement without breaking the calibration seal
  • Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation.
  • 3 year warranty

The Fluke 53 II B and 54 II B include all the features listed above plus:

  • Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG.
  • Additional thermocouple types R, S, and N (for a total of 7 different types)
  • Recall function allows logged data to be easily reviewed on the meter display
  • Infrared USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
  • Data Logging up to 500 points of data with user adjustable recording interval

Specifications

Temperature accuracy

Above -100 °C:

 J, K, T, E, and N-type: ±[0.05% + 0.3°C]*

 

 R and S-type: ±[0.05% + 0.4°C]*

 

 

Below -100 °C:

 J, K, E, and N-types: ±[0.20% + 0.3°C]*

 

 T-type: ±[0.50% + 0.3°C]

 

 

Temperature

J-type:

 -210 °C to 1200 °C

K-type:

 -200 °C to 1372 °C

T-type:

 -250 °C to 400 °C

E-type:

 -150 °C to 1000 °C

N-type:

 -200 °C to 1300 °C *

R and S-type:

 0 °C to 1767 °C *

Temperature scale

 ITS-90

Applicable standards

 NIST-175

Display Resolution

 0.1 °C, 0.1 K < 1000

 1°C, 1 K >=1000

Note

*

 Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples.

 

Environmental Specifications

Operating Temperature

 -10 °C to 50 °C

Storage Temperature

 -40 °C to 60 °C

Humidity (Without Condensation)

 0% to 90%; 0 °C to 35 °C

 0% to 70%; 0 °C to 50 °C

 

Safety Specifications

Overvoltage category

 CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2

Agency Approvals

 CE, CSA, TÜV (pending)

 

Mechanical & General Specifications

Size

 173 mm L x 86 mm W x 38 mm

Weight

 400 g

Batteries

 3 AA batteries; typical 1000-hour life